• High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50
  • High-precision electric parallel gripper EPG-HP26-50

High-precision electric parallel gripper EPG-HP26-50

Five-sided installation,high static and high stiffness

Maximum recommended load :
1Kg
Body weight :
0.45kg
Maximum current :
0.6 A
Rated current :
0.25A

USD: 800

ablity:Monthly Output500

contact shop

Product Description

High-precision electric parallel gripper

High precision is one of the core strengths of this gripper. It can precisely control the opening and closing of the jaws and the grasping force to ensure accurate grasping and placement of objects. In fields such as electronic manufacturing and precision machining, there are extremely high requirements for gripping accuracy of parts, and high-precision electric parallel grippers can meet these strict requirements. It can avoid parts damage or assembly errors caused by inaccurate grabbing, and improve production quality and efficiency.

The high rigidity ensures the stability and reliability of the gripper when grabbing heavy objects or performing high-speed movements. Even if it is subjected to large external force, the clamping jaw will not deform or loosen, ensuring the firmness of grasping. In the logistics industry, clamping jaws need to frequently grab and carry goods of various weights. The high-rigidity design can ensure that the clamping jaws will not malfunction during long-term use, improving the efficiency and safety of logistics operations.

Product parameters

Adjustable stroke0-26mm
Single finger holding force5-50 N
Open/close time0.35s
Position repeatability±0.02 mm
*Maximum recommended load1Kg
Drop detectionsupport
Usage environment5~40°C, below 85% RH
operating noise<40dB
Body weight0.45kg
IP ratingIP40
Rated voltageDC 24±10%V
Maximum current0.6 A
Rated current0.25A
Communication protocolModbus RTU (RS 485)
Comply with international standardsDigitalI/O optional
Allowable static load Fz in vertical
 direction
CE,RoHS
Allowable static moment of slider Mx200N
Allowable static moment of slider My3N.m
Allowable static moment of slider Mz2.5 N.m


Technological Innovation

It has served dozens of benchmark companies in the medical automation, lithium battery, 3C, semiconductor, food and other industries. In particular, the gripping and rotating integrated electric gripper developed for the test tube opening, code scanning and other processes in the medical industry has provided a perfect solution for the medical industry. made contact contributions.

Product Display



The clamping surfaces are parallel and symmetrical, and precise opening and closing are achieved through electric drive. The structure is exquisitely designed and flexible to operate. It can adapt to workpieces of various shapes and sizes, and can quickly and accurately clamp and place workpieces, reduce the complexity and error rate of manual operation, improve production efficiency, and the clamping force is uniform and stable to avoid damage to the workpiece.





It is suitable for grasping and assembling small parts with high precision requirements and limited space, such as electronic component production, small precision machining and other fields.

Size & Interface

Application Cases

During the throat sampling process, high precision and stability of the parallel grippers are crucial, and the operation of the grippers can be controlled by automated equipment.

In the cable processing industry, parallel clamping jaws can achieve rapid stripping of cables. The high precision and adjustability of the clamping jaw allows it to adapt to cables of different diameters, accurately clamp and strip the cable sheath. The use of the clamping jaw can improve the efficiency and quality of wire stripping, and can also be used with automated wire stripping equipment. Combined to achieve fully automated production of cable stripping.

In the laboratory, parallel clamping jaws can conveniently open and close test tubes. It can accurately clamp the test tube cover and easily open or close the test tube, avoiding test tube breakage or sample contamination that may be caused by manual operation. For experiments that require frequent test tube operations, the use of clamping jaws can greatly improve work efficiency.

Recommended products

Electric vacuum actuator LRA

“L+R&quot; DualAxis Integration,Micron-level High Precision Positioning

collect:0

Electric vacuum actuator EVS-08

Small size, AB independent dual control,Suction adjustable

collect:0

Electric vacuum actuator EVS-01

Real-time compensation of vacuum degree, Small volume, large capacity

collect:0

Mini electric parallel gripper EPG-M06-015

Small size, high cost performance, clamping feedback, drop detection

collect:0