Product Description
Low-temperature-resistant incremental encoders are available in Ø38/Ø50 flange sizes, operate in a -40°C to +85°C temperature range, and feature IP54/IP65 protection. They offer selectable output and resolution, reliable mechanical performance, and are suitable for diverse scenarios.
Product parameters
Flange type | Clamping and threaded mounting | |
Flange size | Ø38mm | Ø50mm |
Flange material | Aluminum alloy | |
Wire outlet | Cable outlet(1m) | |
Shaft material | Stainless steel | |
Casing material | Ductile iron | |
Starting torque | ≤1N·cm(without oil seal) | |
Axial load | ≤10N | ≤15N |
Radial load | ≤20N | ≤25N |
Machine speed | ≤5000rpm | |
Vibration | 10g,10~2KHz | |
Shock | 100g,3ms | |
Weight | 150g | 200g |
Operating temperature | -40°C~+85℃ | |
Storage temperature | -40°C~+90℃ | |
IP rating | IP65 | IP54 |
Maximum humidity | 95% non-condensing |
Wiring Method(Cable Outlet)
Signal | VCC | GND(0V) | A | B | Z | Shield |
Wire Color | Red | Black | Green | White | Yellow | Bold Black |
Ø38 Flange Series
Selection Guide
Model | Output Logic | Resolution | Power Supply Voltage* | Shaft Diameter | |
Code | Output Method | ||||
ZOH02 | C(NPN Collector) | A(Positive Logic(High Active)) | 300,360,500,512,600,720,1000.1024,2000,2048,2500 | DC8~30V | Ø6 |
U(PNP Collector) | |||||
P(Push-Pull) |
Dimensional Drawings
Ø50 Flange Series
Selection Guide
Model | Resolution | Power Supply Voltage* | Shaft Diameter | |
Code | Output Method | |||
ZOH04 | C(NPN Collector) | 300,360,500,512,600,720,1000.1024,2000,2048,2500 | DC8~30V | Ø8 |
U(PNP Collector) | ||||
P(Push-Pull) |
Dimensional Drawings
Product Display

Extreme Temperature Resistance: All series support -40°C startup.
Dual Models for Precise Coverage:
ZOH02 Series: Ø6-axis + IP65 protection (dust and water resistant)
ZOH04 Series: Ø8-axis + 25N axial load (heavy-duty only)

Industrial-grade durability: 100g shock resistance and 10g vibration resistance
Precise control: 2500PPR resolution, push-pull, NPN, and PNP outputs for interference resistance
Quality Control
The quality of encoders is directly related to the stability and reliability of industrial automation systems. We have built a full-process quality control system, strictly screening suppliers from raw material procurement to ensure that the performance of core components meets standards; in the production process, we use high-precision equipment and standardized processes, and cooperate with online detection technology for real-time monitoring; in the finished product stage, we conduct rigorous tests such as high and low temperature, electromagnetic compatibility, and life aging to eliminate performance risks. Each encoder has passed multiple quality inspection levels, and its excellent quality has laid a solid foundation for intelligent manufacturing, providing customers with long-term and stable use guarantees.

Application Cases
It is suitable for harsh scenarios such as cold chain warehousing, outdoor industrial equipment, machine tools, mining machinery, food and medical machinery, etc. that require resistance to low temperatures, moisture and dust, and certain loads.
Service
I. Precautions for using the encoder
Places where the ambient temperature does not exceed the storage temperature; places where the relative humidity does not exceed the storage humidity; places where the temperature changes sharply and fogging occurs; places close to corrosive gases and flammable gases; places away from dust, salt, and metal powder; places where water, oil, and medicines are used; places where excessive vibration and impact will be transmitted to the body
II. Precautions for installing the encoder
Electrical components must not be subjected to overvoltage and other phenomena. Please conduct an electrostatic assessment of the setting environment, etc. Do not bring the motor power line close to the encoder; the FG line of the motor and the FG of the mechanical device must be reliably grounded; due to shielding The wire is not connected to the encoder body. Please make sure that the shielded wire is effectively connected to the ground at the user end.
III. Precautions on wiring
When used under the specified power supply voltage, please pay attention to the power supply voltage amplitude drop caused by the long wiring; please do not use the encoder wire and other power wires in the same pipe or bundle them in parallel; please use twisted pair wires for the signal wire and power wire of the encoder wire; please do not apply excessive force to the encoder harness, there will be a risk of disconnection
IV. About encoder warranty
Within twelve months after purchasing our company's products, users can get free warranty when they use them correctly according to the instructions,warning signs and other precautions and cause failures.
The following situations will be charged even during the warranty period: (freight is at your own expense)
1. Failures and damages caused by the user falling to the ground during transportation and handling, improper installation;
2. Failures of this product caused by the machine connected to it;
3. Failures and damages caused by fire, salt water, corrosive gas, abnormal voltage and other natural disasters such as earthquakes, thunder, wind, floods, etc.;
4. Repairs, adjustments, and modifications without the permission of our company (labels are not there or the outer cover is disassembled by yourself).
5. Failures that occur when the product is not used in accordance with the instructions and precautions in the instruction manual.
6. Except when other agreements are signed with the customer.